Define a flex PCB bend radius on a named surface in a named assembly state. A drawing that says only “R2” leaves two questions unanswered: which surface has that radius, and when must the circuit meet it? Start with an installed cross section, the complete local flex thickness, and the assembly or motion sequence. Then specify the inside radius, bend angle, tangent locations and measurement conditions. This article turns that geometry into a drawing and verification package; it does not establish a fatigue-qualified minimum radius.
Engineering note · 8 October 2026. Use the broader flex PCB design guide for routing and construction decisions. Here the question is narrower: how do the electrical, mechanical and manufacturing teams agree on the same physical bend?
Name the radius reference before choosing its value
The inside surface faces the bend center; the outside surface faces away. For an ideal circular bend with uniform finished thickness t and concentric surfaces, the outside radius equals the inside radius plus t. The geometric mid-thickness radius lies halfway between them. These are dimensional relationships, independent of whether the construction survives the bend.
The neutral axis is a mechanical concept: the location with zero longitudinal bending strain under the selected model. In a multilayer flex with copper, dielectric and adhesive, its position requires a construction-dependent analysis. Do not automatically label the geometric mid-thickness line as the neutral axis. Nor should a radius drawn through a copper layer be silently substituted for the finished inside-surface radius.
Build the section from the real installation
Take a section normal to the bend axis, through the location most likely to constrain the circuit. Include the enclosure, guide, connector body, stiffener edge, clamp and nearby fastener. Identify what physically locates the flex and what merely appears close to it in CAD. A connector-held tail and a loosely retained loop have different boundary conditions even when their final silhouettes look similar.
Use finished local thickness, including copper, base film, coverlay and adhesive where present. A thickness assigned to the connector termination may include a stiffener absent from the bend zone. Conversely, an overlapping coverlay or bonding feature can make the bend thicker than the nominal laminate. Track those region boundaries on the drawing. The earlier article on typical and guaranteed laminate values explains why a supplier’s nominal input needs an agreed finished-construction tolerance.
Capture more than the final pose. A wearable sensor folded once into its enclosure may encounter a tighter bend while a technician closes the housing. A robotic wrist loop may change shape during travel and reverse curvature. A service-removable industrial sensor may be straightened and refolded repeatedly. Record installation, operation and servicing separately instead of describing every application as “static.”
Choose a reference that can be inspected
| Observed condition | Drawing reference | What must be checked |
|---|---|---|
| Flex conforms to a circular guide | Finished inside surface, plus guide datum | Contact, guide tolerance, clearance and retention through installation |
| CAD uses a mid-thickness arc | Explicit geometric middle radius and local thickness | Convert to inside/outside radii; identify which face the exported model represents |
| Free loop changes shape | Minimum local inside radius over the defined motion envelope | Inspect critical travel positions and intermediate states; one circle does not describe the entire loop |
| Bend begins near a stiffener | Inside radius and tangent location relative to the stiffener edge | Localized curvature, adhesive boundary and assembly restraint |
| Tool forms the circuit before installation | Tool geometry and released installed geometry, separately | Forming sequence, relaxation, contact pressure and measured final shape |
A mandrel’s radius is the circuit’s inside radius only where the inside surface actually conforms to that mandrel. An air gap, a loose loop or a contact point at a housing edge breaks that equivalence. For a noncircular bend, report local curvature rather than fitting one convenient circle across the entire profile.
Worked example: a 90-degree enclosure turn
Illustrative assumptions, not a material recommendation: an installed circular quarter-turn, inside radius 2.00 mm, uniform finished thickness 0.20 mm, and no stiffener in the bend zone. Both surfaces are assumed concentric. No copper strain, material modulus, cycle life or forming allowance is assumed.
- Outside radius: 2.00 + 0.20 = 2.20 mm.
- Geometric middle radius: 2.00 + 0.20/2 = 2.10 mm.
- Middle-line arc length: radius × angle in radians = 2.10 × π/2 ≈ 3.30 mm.
The last value describes the middle line in the ideal installed shape. It is not, by itself, a released flat-pattern length: straight runs, tangent positions, retention, material deformation and the CAD model’s reference still need agreement. The outer surface also sits 0.20 mm beyond the inside surface; an enclosure clearance check using only the inside arc misses that occupied space.
If “R2.00” actually meant the geometric middle, the inside radius would instead be 2.00 − 0.10 = 1.90 mm. For a tolerance example, assume the drawing permits middle radius 2.00 ± 0.05 mm and thickness 0.20 ± 0.02 mm. Conservative dimensional extremes give inside radius 1.95 − 0.22/2 = 1.84 mm, and outside radius 2.05 + 0.22/2 = 2.16 mm. These are illustrative geometric bounds, not measured production capability or a fatigue verdict.
Translate the section into ECAD and MCAD
Check the actual radius convention used by the software and design mode. Altium’s Advanced Mode bending-line documentation defines its Radius parameter as an orthogonal distance from the board-region surface to the point about which bending occurs. It also ties the displayed bend zone to angle and radius, and associates bending lines with selected stack regions. A field named Radius therefore needs interpretation against the installed section rather than an assumed neutral-plane convention.
Make a simple reference bend in the project, measure the exported cross section, and record which surface is dimensioned. Give the bend and stack region stable names. Check fold direction, active region, thickness and tangent positions after transfer to the mechanical assembly. Verify clearances in the folded assembly and along the installation path. A successful 3D fold confirms modeled geometry; it does not demonstrate manufacturing compatibility or electrical continuity after cycling.
What changes the manufacturing review
A tighter available envelope may drive a thinner local construction, removal of unnecessary layers from the moving region, or relocation of a stiffener. Each choice changes other requirements: conductor resistance, reference-plane continuity, handling, connector thickness or assembly support. Resolve those tradeoffs with the electrical and fabrication teams before altering the material stack solely to make a model fit.
Altium’s static and dynamic flex discussion identifies total thickness and repeated bending as mechanical considerations. That supports reviewing the construction and duty together; it does not justify copying a generic radius multiplier into a product-life guarantee. Agree an application-specific construction, bend envelope and validation plan.
Give the fabricator a section and local thickness requirement alongside the flat artwork. State where stiffeners, coverlay changes, vias, components and bonded restraints end relative to the bend tangents. Use the flex DFM checklist to review those boundaries. Keep the assembly instruction separate from fabrication tolerances so operators can reproduce the intended installed geometry without guessing.
Verify geometry first, then performance
- Identify the specimen. Record drawing revision, construction, actual local thickness and relevant material lot information.
- Measure the assembly state. Use a calibrated side-view method or accessible inspection fixture. Record the named surface, tangent locations, scale and uncertainty; avoid measuring radius from an oblique photograph.
- Check the worst positions. Include housing closure and service handling. For motion, inspect travel extremes and intermediate positions where the loop can kink or rub.
- Test the defined duty. Specify travel, speed, cycles, environment and electrical acceptance criteria before testing. Monitor continuity as appropriate to detect intermittent faults during movement.
- Inspect afterward. Compare installed shape, abrasion, creases, coverlay condition and electrical results against the pre-agreed criteria. Record failures instead of treating visual fit as acceptance.
For drawing release, a useful note identifies: “Bend B1; finished inside surface; installed state shown in section A–A; local thickness per stack F1; angle and tangent positions per drawing; installation sequence per assembly instruction.” Supply numerical limits only after the responsible teams have agreed them. Geometric clarity makes that review possible; qualification supplies the evidence that the selected construction meets its service requirement.
Bring the installed section to the design review
Prepare the application, quantity, drawing revision, layer count and material construction, installed section, motion or assembly duty, target delivery date and unresolved questions. Highlight whether your radius is inside-surface or geometric middle, and which measurement state applies. For initial contact, WhatsApp +86 139 1806 6072 is also available.
Once the installed section is defined, send it with the regional construction and the controlled fabrication files. The note on inputs for a meaningful flex DFM review explains how to identify open interface decisions and close manufacturing findings against the same revision.
For an enclosure-constrained application, apply the installed-section method to smartwatch flex routing around the battery and display, including connector access and the local space budget.
When the installed section moves inside a robot joint, add attachment-frame rotation and the full trajectory to the geometry check. See robot wrist flex routing and twist-limit definition for an installation-offset example and combined-motion verification checklist.