Separate connection need from convenient placement

List the layer changes that are electrically necessary and locate their proposed vias on the regional drawing. Consider whether routing can bring them into a stable supported area. Review conductor paths before adding layer transitions simply to shorten a route. A CAD tool can permit a via without understanding how that location moves in the product.

Via review by function

Review itemDesign questionEvidence or action
Signal layer changeCan the transition occur outside the active span?Compare routing alternatives
Thermal or power connectionWhat electrical or thermal path is intended?Document load and construction assumptions
Test accessWill probing damage or load the flexible area?Define a supported probing arrangement
Exposed holeDoes coverlay intentionally leave it accessible?Coordinate opening and registration requirements

Describe the plated structure

Identify which layers are connected, whether the hole is plated, and how local copper buildup is represented in the stackup. Check exposed annular areas and coverlay access with the fabricator. Use actual agreed hole and land rules; do not assume a rigid-board default is suitable for a different flex process or construction.

Review nearby mechanical discontinuities

Inspect the relationship among a via, stiffener edge, fold region, mounting point, and component pad. If the feature cannot leave a loaded region, call it out as a specific review and validation item. Agree what inspection or sectioning evidence is needed for the prototype. Keep those requirements separate from the electrical test, which answers a different question.

Before you release the design

  • Mark via locations on the mechanical region map.
  • Confirm plated and non-plated holes are unambiguous in output files.
  • Review hole, land, and coverlay requirements as a set.
  • Assign representative inspection to any unusual interconnect feature.

Watch points

  • A passing netlist test does not demonstrate mechanical endurance of a via.

Practical questions

Are vias forbidden on all flex circuits?

No. Many flex constructions use interlayer connections. Their structure and location must fit the construction and duty; blanket placement rules cannot replace a regional review.

Can I tent every via with coverlay?

Discuss the actual insulation process and intended access with the fabricator. Coverlay openings, adhesive behavior, and assembly requirements differ from a rigid-board solder-mask assumption.

Technical references

References support the material or design context. Check the exact grade, part number, document revision and project conditions before release.

Updated 27 September 2026 · Technical content policy · Engineering guidance supports project review; the agreed drawing defines the build.